Process description. Calibration Steps: STAJE 1 - Activation and configuration Activate Programm Mode Read the Joystick Config Firmware Hardware Read the sensor Config STAJE 2 - Filter and Range settings Filter settings Activate Sensor #x for calibration Write Filter param in a Sensor #x Save Filter param in a Memory Read "Forward" (Max Positive direction of current Axis) Read "Backward" (Max Negative direction of current Axis) Range coefficient calculation Write Range param in a Sensor #x Save Range param in a Memory STAJE 3 - Sensityvity and VOQ settings (Range adjustmen) Sensor Range calculation Read "Forward" (Max Positive direction of current Axis) Read "Backward" (Max Negative direction of current Axis) Sensitivity calculation Write Sensitivity param in a Sensor #x Read "Neutral" and calculate VOQ settings (Joistick is released on current Axis) Write VOQ settings in a Sensor #x Save Range param and VOQ settings in a Memory Sensitivity Adjustment Write Adjustment data in a Sensor #x If axis support more sensors - swich to the next and start from STAJE 2 STAJE 4 - Compensation Table creation Activate All Sensors Activate "creation of Compensation Table" procedure Create Compensation Table (moving the Joistick from Max to Min position on current Axis) If the Joistick support more Axes swich to the next Axis / Sensor and start from STAJE 2 Close the Programm Mode